    Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
    SC-4 security expansion module
    SM-602 programmable safety controller

    As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

    (1) Redundancy

    (2) Difference

    (3) Self-detection


       How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

    SC-4 security expansion module

    841056c.png

    · Is a safety relay output expansion module.

    · Receive the on-site safety switch signal, and expand it into 4 NO (normally open) safety output contacts and 2 NC (normally closed) auxiliary output contacts. 
    · Two auxiliary contacts can be used for output status indication and fault feedback respectively.

    Product selection     0523ce09f27183840accf49d6c9b5a4.png

    product name

    model

    Safety input

    Safe output

    order number

    SC-4

    24V DC

    Safety switch, contact switch

    4NO+2NC

    LHS
    explain

    Safety switch, contact switch


    safety performance

    ·Performance level (PL): PLE

    ·Safety category (cat.): cat.4.

    ·Task time (TM): 20 years.

    ·Diagnostic coverage (DC/DC AVG): 99%

    ·Safety integrity level (SIL): SIL3

    ·Hardware fault margin (HFT): 1

    ·Safety Failure Score (SFF): 99%

    ·PFHD: 1.78e-9/h

    ·Stop category: 0           

    Comply with the standard EN ISO13849

    Comply with the standard EN ISO13849

    Comply with the standard EN ISO13849

    Comply with the standard EN ISO13849

    Comply with standards IEC61508, IEC62061.

    Comply with standards IEC61508, IEC62061.

    Comply with standards IEC61508, IEC62061.

    Comply with standards IEC61508, IEC62061.

    Comply with standard EN 60204-1.


    Main technical parameters

    Power supply characteristics

    ·Power supply voltage: 24VDC

    ·Voltage range: -15%~+10%

    ·Current loss: ≤70mA(24VDC)

    Input characteristics

    ·Input current: ≤70mA(24VDC)

    ·Conductor resistance: ≤15Ω

    ·Input equipment: safety switch, contact switch.

    output characteristic

    ·Number of contacts: 4NO+2NC

           Safety outputs: 13, 14, 23, 24, 33, 34, 43, 44.

           Auxiliary outputs: 11, 12 (status)

           Y1, Y2 (feedback)

    ·Contact material: AgSnO2+0.2 μm Au.

    ·Contact type: forced guidance

    ·Contact fuse protection: 10A gL/gG, NEOZED (normally open contact)

           6A gL/gG, NEOZED (normally closed contact)

    ·Switching capacity (en 60947-5-1): AC-15, 5a/230v; DC-13, 5A/24V

    ·Mechanical life: more than 107 times

    Time characteristic

    ·Suction buffer time: ≤30ms

    ·Release buffer time: ≤20ms

    ·Recovery time: ≤1000ms

    ·Short interruption of power supply: 20ms


    Environmental characteristic parameters

    ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

    ·Vibration frequency: 10Hz~55Hz

    ·Vibration amplitude: 0.35mm

    ·Operating temperature: -20℃~+60℃

    ·Storage temperature: -40℃~+85℃

    ·Relative humidity: 10%~90%

    ·Electrical clearance and creepage distance: in accordance with EN60947-1.

    ·Overvoltage grade: Ⅲ

    ·Pollution level: 2

    ·Altitude: ≤2000m

    ·Rated isolation voltage: 250VAC.

    ·Rated impulse voltage: 6000V(1.2/50us)

    ·Insulation strength: 1500VAC for 1min.

    841056c.png


    Functional application parameters

    functional block diagram

    Typical application

    圖片2.png

    典型應用圖.png


    Overall dimensions (depth× height× width):

    Overall dimensions (depth× height× width):114.5mm×99.0mm×22.5mm

    Net weight of product200g

    外形尺寸圖.png


    Wiring diagram

    Power supply/input loop

    Switch input

    電路圖1.png

    Output loop

    電路圖2.png

    feedback loop

    電路圖3.png


    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 伊在人香蕉99久久| 亚洲 成人 无码 在线观看| 丰满人妻被黑人中出849| 欧美日韩国产码高清| 古蔺县| 老熟女搡BBBB搡BBBB视频| 平塘县| 中文字幕日韩精品人妻| 亚洲中文字幕精品久久久久久动漫 | 久久岛国片| WWW1234麻豆黑丝诱惑吃瓜| 国产精品一区二区AV不卡| 国产成人一区在线播放| 中国凸偷窥XXXX自由视频| 久久这里只有精品免费首页| 亚洲播播| 少妇洁白无删减版178txt| 人妻无码中文专区久久综合 | 人妻精品动漫H无码中字| 综合色一色综合久久网| 97青草香蕉依人在线播放| 无码黑人精品一区二区| 欧美日韩免费观看视频| 欧美一区二区三区欧美日韩亚洲 | 国产精品久久久久影院老司| 国产激情A∨在线视频播放| 亚洲色欲久久久久综合网 | 69avav?cn| 狠狠色婷婷久久综合频道日韩 | 亚洲精品一区二区三区蜜桃| 日韩一区二区三| 亚洲欧洲美洲无码精品va| 抚宁县| 99热这里有免费国产精品| 97亚洲精品| 99中文在线精品| 男人添女人囗交做爰视频| 丰满熟女人妻中出系列| 国产精品看高国产精品不卡| 又粗又长美女电影在线| 女人喷水高潮时的视频网站|