    Position首頁 > Home > Industrial Safety Products > Safety interlock switch > RFID Electromagnetic Locking Safety Door Switch
    D3SL-T/RFID electromagnetic locking type
    1.png

    ·Electromagnetic force locking 500N

    ·Adopt a small plane "electromagnetic" locking structure.

    ·Support 16 to 20 cascaded connections.

    ·Design of permanent magnet in matcher

    ·Small body, simple installation

    ·Full-angle eye-catching indicator light

    ·No abrasive powder will be produced.

    ·IP65/IP67 protection


    D3SL-T/RFID Series Selection Table

    Locking mode

    deploy

    model

    Output mode

    coded system

    Electromagnetic locking

    normalized form

    D3SL-T-DB-N2

    NPN

    universal coding

    D3SL-T-DB-N1

    NPN

    Unique coding

    D3SL-T-DB-P2

    PNP

    universal coding

    D3SL-T-DB-P1

    PNP

    Unique coding

    Advanced type

    D3SL-T-DG-N2

    NPN

    universal coding

    D3SL-T-DG-N1

    NPN

    Unique coding

    D3SL-T-DG-P2

    PNP

    universal coding

    D3SL-T-DG-P1

    PNP

    Unique coding


    Technical parameters of D3SL-T/RFID

    type

    Hinged door

    small-sized

    M12 connector

    normalized form

    High functional type

    working distance

    Sao(off-0n)

    4mm

    Sar(on-0ff)

    4mm

    Response time

    Lock → release

    155ms

    Release → lock

    155ms

    Detection → Non-detection

    20ms+2ms* (Number of cascaded connections -1)

    Non-detection → detection

    300ms+25ms* (Number of cascaded units -1)

    Control output

    (OSSD output)

    Output mode

    Transistor output "2

    Maximum load current

    150mA

    Residual voltage (on)

    Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

    OFF voltage

    Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

    leakage current

    Up to 0.5mA

    Maximum load capacity

    0.8uF

    Load connection resistance

    Max. 2.5 Euro

    AUX output

    (Non-safety system output)

    Output mode

    Transistor output

    Maximum load current

    50mA

    Residual voltage (ON)

    Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

    external input

    (Short-circuit current)

    Safety input

    About 1.5 max 2

    Locking control input OSSD action switching input

    About 2.5 mA

    Reset /EDM input

    About 5mA (high functional type only)

    EDM select input

    About 2.5 mA (high functional type only)

    Power Supply 

    Power supply voltage

    24 VDC 10% including ripple (P-P)10% Class2

    consumed power

    <5W

    protective circuit

    Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

    Environmental resistance

    Enclosure protection grade

    IP65/67(IEC60529)

    Operating ambient temperature

    20 degrees below zero to 55 degrees without freezing.

    Storage ambient temperature

    25 degrees below zero to 70 degrees without freezing.

    Using ambient humidity

    5% to 95%RH

    Storage environment humidity

    5% to 95%RH

    Vibration resistance

    10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

    Applicable standards

    ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


    Model description of safety switch

     1728548977520914.png 



    hookup

    Standard type (NPN, cascade)

    Standard (PNP, cascade)

    1719978292858022.png

    Standard type (NPN, cascade)

    1719978426648983.png

    Standard (PNP, cascade)

    1719978725470017.png

    Functional (NPN, cascade)

    Functional (PNP, cascade)

    1719979076106539.png

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    "1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

    S: reset switch

    "Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

    "1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    High functional type (NPN, cascade)

    1719979521976024.png

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

    3. EDM only: Turn off the EDM selection (chalk line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    Functional (PNP, cascade)

    1719979875434469.png

    Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

    S: reset switch

    Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

    *1. Make ?EDM and reset: wire as shown in the figure.

    2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

    3. EDM only: Turn off the EDM selection (chalk line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch


    Indication of indicator light

    1719983442751425.png


    Product ruler diagram

    1719983681983392.png


    Selection Method of Safety Switch D3SL-T/RFID Series

    1728618489514684.png



    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 亚洲 中文 欧美 日韩 在线| 老司机亚洲精品| 丝袜美腿视频一区二区三区| 久久黄色网| 亚洲12色吧| 亚洲婷婷国产色五月| 日韩天码| 亚洲精品无码一区二区| 国产超碰AV人人做人人爽| JIZZ亚洲| 性交大片| 一本色道久久综合亚洲精品按摩 | 中国凸偷窥XXXX自由视频| 女人与公狼做交十配视频| 亚洲精品999| 亚洲日韩国产精品第一页一区| 18禁裸乳无遮挡自慰免费动漫| 日韩av手机免费观看| 让少妇高潮无乱码高清在线观看| 日韩欧美一区二区三区| 色色图区| 在线无码| 中文字幕日本最新乱码视频| 久久久久久亚洲AV无码专区| 亚洲国产欧美在线人成| 女人的天堂av| 无码里番纯肉h在线网站| 国内久久婷婷精品人双人| 中文字幕不卡av| 国产精品午夜福利视频| 久久99精品国产99久久6尤物| 鲜嫩高中生无套进入| 亚洲欧美日本一区二区| 亚洲精品国产电影| www.99| 成人做爰69片免费看网站| 午夜激情网站| 亚洲综合色成在线播放| 华坪县| 日韩一区二区三区无码影院| 男人天堂网址|